Biomechanical Properties of Synthetic Mesh Reconstructed Glenohumeral Joint Capsule


Department of Orthopaedic Oncology Surgery, Beijing Jishuitan Hospital, Peking University, Beijing 100035, China

Date of Submission09-Feb-2017
Date of Web Publication7-Jul-2017

Correspondence Address:
Xiao-Hui Niu
Department of Orthopaedic Oncology Surgery, Beijing Jishuitan Hospital, Peking University, Beijing 100035
China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0366-6999.209883

Rights and Permissions
  Abstract 


Keywords: Biomechanical; Shoulder Joint; Stability; Synthetic Mesh; Tumors


How to cite this article:
Jin T, Liu WF, Xu HR, Li Y, Niu XH. Biomechanical Properties of Synthetic Mesh Reconstructed Glenohumeral Joint Capsule. Chin Med J 2017;130:1743-4

How to cite this URL:
Jin T, Liu WF, Xu HR, Li Y, Niu XH. Biomechanical Properties of Synthetic Mesh Reconstructed Glenohumeral Joint Capsule. Chin Med J [serial online] 2017 [cited 2017 Jul 22];130:1743-4. Available from: http://www.cmj.org/text.asp?2017/130/14/1743/209883

Synthetic mesh is often used in soft tissue reconstruction after artificial prosthesis replacement for patients with proximal humeral bone tumors. We carried out biomechanical and histological tests on two amputated extremities to test the stability of the joint and the biocompatibility of the synthetic meshes.

Two samples of amputated extremities were included in this study. Case 1 is a 31-year-old female who underwent artificial prosthesis replacement in treatment of Grade II chondrosarcoma in 2009. Parts of the starting point of deltoid muscle and the ending point of pectoralis major muscle were excised, and the brachial artery, median nerve, musculocutaneous nerve, axillary nerve, and radial nerve were remained. Then, a humeral prosthesis was implanted, a monofilament polypropylene fiber mesh (Bard ® Mesh 26 cm × 36 cm) was fixed to the capsule, and four rivets were placed around the shoulder cup to reconstruct the soft tissue. Recurrence was observed in October 2013, forequarter amputation was performed, and the specimen was stored at −20°C.

Case 2 is a 54-year-old male patient with chondrosarcoma of the proximal humeral bone. The same resection and reconstruction surgery as case 1 was performed in 2013, except for the synthetic mesh was only covered the surface of the prosthesis but not fixed to the joint capsule. Recurrence was observed in March 2015, interscapular thoracic amputation was performed, and the specimen was stored at −20°C.

MTS858 Mini Bionix II (MTS Systems Corporation, USA) was used for the biomechanical studies; the load applied was 2–10 kN. The specimen was fixed on the equipment by a specifically designed clamper.

The methods of biomechanical test followed the instruction of Alexander cadaveric shoulder joint test.[1] The scapula was fixed and the load was exerted on the head of the humerus. Movement of the head of the humerus under a certain load on scapula was used as an index of shoulder joint stability. Stability of the reconstructed joint capsule was compared to the normal value.[1]

Procedures of preparing and embedding the specimen followed the methods described by van de Sande et al.[1] Then, the specimen was fixed to the test equipment using the specifically designed fixation system. To minimize the effect of soft tissue glutinosity to the test result, the humeral bone was placed 30° abduction position of scapular plane. The scapular bone was fixed, and the humerus was externally rotated 10 times with the force of 0.5 N·m.

Measurement of the stability: The scapula was fixed, and the humeral bone was adjusted by the equipment to two positions: (1) 0° abduction and neutral rotational position and (2) 30° abduction and neutral rotational position. A force of 1N–20N on upright, downright, forward, and backward directions was enforced, and the movement was measured to calculate the stability. The joint capsule was kept intact during the whole procedure.

The data are listed in [Table 1]. The stability of the reconstructed joint was close to that of normal control group which was reported in the literature [1] in a different direction in case 1; however, the result in case 2 was not as good as case 1.
Table 1: Movement of the head of humeral bone with 20 N force compared with the value of normal control subjects in the literature

Click here to view


Histopathologic observation: A piece of the synthetic mesh in case 1 was used for histological studies. Mature fibrous connective tissues were observed around the synthetic mesh. Scattered or a layer of multinucleated giant cells can be observed between the synthetic mesh and fibrous connective tissues, and the fibrous tissues have grown into the synthetic mesh, proving the fine biocompatibility of the synthetic mesh.

A stable shoulder joint is required when arms are performing necessary functions, and it improves patients' quality of life. Wittig et al.[2] proposed that the aim of shoulder joint reconstruction is to gain stability but not function. The current research had focused on the stability of shoulder joint after reconstruction and obtained biomechanical and biocompatibility outcomes of monofilament polypropylene fiber mesh used in shoulder joint reconstruction surgery.

In case 1, stability of shoulder joint is not worse than normal controls, and the patient reported no pain due to instability of the joint after surgery. Stability of the joint in case 2 is not as good as case 1; this could be the result of the difference reconstruct methods. Moreover, the fact that patient in case 2 is older than that in case 1 may affect the stability of the reconstruction.[3]

The synthetic mesh provides the prosthesis with instant stability, but to provide long-term stability, it should be integrated in the surrounding environment by scar tissue formation. A previous study [4] found that Bard synthetic mesh could be integrated with the soft tissues when used in reconstructing ligamentum patellae. The result of case 1 is similar to the previous findings.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
van de Sande MA, Dijkstra PD, Taminiau AH. Proximal humerus reconstruction after tumour resection: Biological versus endoprosthetic reconstruction. Int Orthop 2011;35:1375-80. doi: 10.1007/s00264-010-1152-z.  Back to cited text no. 1
[PUBMED]    
2.
Wittig JC, Bickels J, Kellar-Graney KL, Kim FH, Malawer MM. Osteosarcoma of the proximal humerus: Long-term results with limb-sparing surgery. Clin Orthop Relat Res 2002;397:156-76. doi: 10.1097/00003086-200204000-00021.  Back to cited text no. 2
    
3.
Potter BK, Adams SC, Pitcher JD Jr., Malinin TI, Temple HT. Proximal humerus reconstructions for tumors. Clin Orthop Relat Res 2009;467:1035-41. doi: 10.1007/s11999-008-0531-x.  Back to cited text no. 3
[PUBMED]    
4.
Xu HR, Niu XH, Zhang Q, Hao L, Ding Y, Li Y. Biomechanical characteristics and histological features of polypropylene mesh for the reconstruction of patellar ligament attachment after resection of proximal tibia bone tumors (in Chinese). Chin J Bone Joint 2012;6:627-30. doi: 10.3969/j.issn. 2095-252X.2012.06.017.  Back to cited text no. 4
    



 
 
    Tables

  [Table 1]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
References
Article Tables

 Article Access Statistics
    Viewed58    
    Printed0    
    Emailed0    
    PDF Downloaded9    
    Comments [Add]    

Recommend this journal




京ICP备05052599号